OliNo

Renewable Energy

LEDITLIGHT – 360degrees SMD LED-lamp – 5Watt – warm-white 76 lm/W

Posted by Marcel van der Steen in Led lights, Light measurements Add comments

lil_30smde27 presents a led lamp that emits light in all directions. This lamp emits a warm white light.

This article shows the measurement results. Many parameters are also found in the Eulumdat file.

See this overview for a comparison with other light bulbs.

Summary measurement data

parameter meas. result remark
Color temperature 2950 Warm white
Luminous intensity Iv 1 Cd Measured straight underneath the lamp. This value is low, as the light bulb emits its light to the sides.
Beam angle 360 deg Valid for all C-angles as there is symmetry along the 1st axis. This light emits in all directions, except in the direction exactly below and above.
Power P 4.5 W
Power Factor 0.33 For every 1 kWh net power consumed, there has been 2.9 kVAhr for reactive power.
Luminous flux 341 Lm
Luminous efficacy 76 Lm/W
CRI_Ra 62 Color Rendering Index.
Coordinates chromaticity diagram x=0.4465 and y=0.4169
Fitting E27
PAR-value 0.3 μMol/s/m2 The number of photons seen by an average plant when it is lit by the light of this light bulb. Value valid at 1 m distance from light bulb.
PAR-photon efficacy 0.6 μMol/s/We The toal emitted number of photons by this light, divided by its consumption in W. It indicates a kind of efficacy in generating photons.
S/P ratio 1.0 This factor indicates the amount of times more efficient the light of this light bulb is perceived under scotopic circumstances (ow environmental light level).
D x H external dimensions 32 x 103 mm External dimensions of the lamp (D = diameter).
D x H luminous area 32 x 60 mm Dimensions of the luminous area (used in Eulumdat file). This is equal to the surfaces on which leds are mounted.
General remarks The ambient temperature during the whole set of measurements was 22.5-24.5 deg C. The temperature of the lamp gets about 44 degrees hotter than ambient.
Warm up effect: during the warm up time the illuminance decreases with ≈5 % and the consumed power with 9 %.

Voltage dependency: the power consumption and illuminance do depend linearly on the voltage when it is varied from 200 – 250 V.

Measurement report (PDF) tbc
Eulumdat file olino_eulumdat Right click on icon and save the file.

Overview table

lil_30smde27_summary2

The overview table is explained on the OliNo website. Please note that this overview table makes use of calculations, use this data with care as explained on the OliNo site. E (lux) values are not accurate, when within 5 x 60 mm = 300 mm. Within this distance from the lamp (looking sideways tat the lamp, as there is no light towards above and below), the measured lux values willl be less than the computed values in this overview as the measurements are then within the near field of the lamp.

Note as well that the beam angle > 180 degrees and hence the sizes of the light spot in the column Ø50cm do not have a physical meaning and should be discarded.

Eulumdat light diagram

This light diagram below comes from the program Qlumedit, that extracts these diagrams from an Eulumdat file. It is explained on the OliNo site.

lil_30smde27_light_diagram

The light diagram giving the radiation pattern.

It indicates the luminous intensity around the light bulb. The directions C90-C270 and C0-C180 give the same result as there is a symmetry along the 1st axis.

Illuminance Ev at 1 m distance, or luminous intensity Iv

Herewith the plot of the averaged luminous intensity Iv as a function of the inclination angle with the light bulb.

lil_30smde27_pp_avg

The radiation pattern of the light bulb.

This radiation pattern is the average of the light output of the light diagram given earlier. Also, in this graph the luminous intensity is given in Cd.

These averaged values are used (later) to compute the lumen output.

lil_30smde27_ev_dep_kantelhoek

Intensity data of every measured turn angle at each inclination angle.

This plot shows per inclination angle the intensity measurement results for each turn angle at that inclination angle. There normally are differences in illuminance values for different turn angles. However for further calculations the averaged values will be used.

When using the average values per inclination angle, the beam angle can be computed, being 360º.

Luminous flux

With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible to compute the luminous flux.

The result of this computation for this light spot is a luminous flux of 341 Lm.

Luminous efficacy

The luminous flux being 341 Lm, and the power of the light bulb being 4.5 W, yields a luminous efficacy of 76 Lm/W.

Electrical properties

A power factor of 0.33 means that for every 1 kWh net power consumed, a reactive component of 2.9 kVAr was needed.

Lamp voltage 230 VAC
Lamp current 60 mA
Power P 4.5 W
Apparent power S 13.7 VA
Power factor 0.33

Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See the OliNo site how this is obtained.

lil_30smde27_u_i_waveforms

Voltage across and current through the lightbulb

This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the explanation on the OliNo website.

lil_30smde27_harmonics

Harmonics in in the current waveform and checked against IEC61000-3-2:2006

There are no limits for the harmonics for led lighting equipment <= 25 W.

The Total Harmonic Distortion of the current is computed as 37 %.

Temperature measurements lamp

ir000150

Temperature image (overview) of the light bulb

Tape was not needed as the martial of the lamp is very diffuse (a plastic).

status lamp > 2 hours on
ambient temperature 24 deg C
reflected background temperature 24 deg C
camera Fluke Ti25
emissivity 0.95(1)
measurement distance 0.30 m
IFOVgeometric 0.8 mm
NETD (thermal sensitivity) 100 mK

(1) The emissivity is set at 0.95 which is close to the value of a diffuse surface.

The hottest temperature is about 68 deg C. As the material is basically an insulator it does not conduct the heat very quickly and it is safe to touch it (meaning it will not burn). The temperature however still gets relatively high.

Color temperature and Spectral power distribution

lil_30smde27_powerspectrum_at_1m_distance

The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.

The measured color temperature is about 2950 K which is warm white.

This color temperature is measured straight underneath the light bulb. Below a graph showing the color temperature for different inclination angles.

lil_30smde27_cct_function_of_incl

Color temperature as a function of inclination angle.

The measurement of CCT is measured for inclination angles up to 90º.

The beam angle is maximally 360º, meaning a 180º inclination angle. In this area all the light is present. The variation in correlated color temperature in the first 90 degrees inclination angle (more in not measured) is about 2 %.

PAR value and PAR spectrum

To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See the OliNo website how this all is determined and the explanation of the graph.

lil_30smde27_par_spectra_at_1m_distance

The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb

parameter value unit
PAR-number 0.6 μMol/s/m²
PAR-photon current 2.7 μMol/s
PAR-photon efficacy 0.6 μMol/s/W

The PAR efficiency is 62 % (valid for the PAR wave length range of 400 – 700 nm). So maximally 62 % of the total of photons in the light is effectively used by the average plant (since the plant might not take 100 % of the photons at the frequency where its relative sensitivity is 100 %).

S/P ratio

The S/P ratio and measurement is explained on the OliNo website. Here the results are given.

lil_30smde27_s_and_p_spectra_at_1m_distance
The power spectrum, sensitivity curves and resulting scotopic and photopic spectra (spectra energy content defined at 1 m distance).

The S/P ratio is 1.0.

More info on S/P ratio can be found on the OliNo website.

Chromaticity diagram

lil_30smde27_chromaticity

The chromaticity space and the position of the lamp’s color coordinates in it.

The light coming from this lamp is at a small distance from the Planckian Locus (the black path in the graph).

Its coordinates are x=0.4465 and y=0.4169.

Color Rendering Index (CRI) or also Ra

Herewith the image showing the CRI as well as how well different colors are represented (rendered). The higher the number, the better the resemblance with the color when a black body radiator would have been used (the sun, or an incandescent lamp). Practical information and also some critics about the CRI can be found on the OliNo website.

Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.

lil_30smde27_cri

CRI of the light of this lightbulb.

The value of 62 is lower than 80 which is considered a minimum value for indoor usage.

Note: the chromaticity difference is 0.0037 indicates the distance to the Planckian Locus. There is no norm yet that states what the max deviation from white light is allowed to be.

Voltage dependency

The dependency of a number of lamp parameters on the lamp voltage is determined. For this, the lamp voltage has been varied and its effect on the following light bulb parameters measured: illuminance E_v [lx], the lamppower P [W], the (Correlated) Color Temperature [K] and the luminous efficacy [Lm/W].

lil_30smde27_voltagedependency

Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.

The illuminance and consumed power do vary in a linear way when the voltage is varied.

When the voltage at 230 V varies with + and – 5 V, then the illuminance varies < 3 %, so when abrupt voltage changes occur this effect is not visible in the illuminance output.

Warm up effects

After switch on of a cold lamp, the effect of heating up of the lamp is measured on illuminance E_v [lx], color temperature CT or correlated color temperature CCT [K], the lamppower P [W] and the luminous efficacy [lm/W].

lil_30smde27_startupeffect

lil_30smde27_startupeffect_end

Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.

The warm up time is about 30 minutes. During that time the illuminance decreases with ≈ 9 % and the consumed power decreases 9 % as well.

Leave a Reply

WP Theme & Icons by N.Design Studio
Privacy Policy Entries RSS Comments RSS Log in